2013年7月19日 星期五

HW VSP3 - Virtual Serial Port

Index >> Software

Czech version


English version

HW VSP3 - Virtual Serial Port

HW VSP is a software driver that adds a virtual serial port (e.g. COM5) to the operating system and redirects the data from this port via a TCP/IP network to another hardware interface, which is specified by its IP address and port number. HW VSP3 support even NT Services and 64 bit Windows 8 .

Previous version of HW VSP is here: HW Virtual Serial Port

Main Features

DOWNLOAD & Links
  • Free, unrestricted Virtual Serial Port driver for any TCP/IP devices
  • Compatible with Windows 2000, XP (Win 98, NT), Windows 8 NEW& even 32-bit or 64 bit.
  • Runs as a standalone application, or as a NT service suitable for servers NEW
     
  • Option to start at Windows startup and minimize to System Tray
  • Single-port (free) and multi-port (commercial) version
  • Supports RFC 2217, allowing to change remote serial port parameters (such as speed, parity, stop bits) over TCP using NVT
  • VSP driver typically operates as a “TCP client”; however, it can also be used as a “TCP server” (useful for GPRS applications)
  • Configuration stored in an INI file
  • Configuration protected with a password
  • Supports UAC (User Account Control)
  • This software is FREEWARE, as long as you comply with the license terms and conditions 

New in HW VSP3

  • Single-port and multi-port version:
    • Single-port version of HW VSP3 is available freely
    • Multi-port version is available only for HW group products
  • Runs as a stand-alone application, or as a NT service suitable for servers
  • Complete support for Windows 8
  • Supports all 32-bit or 64-bit Windows systems, including Server versions
  • Configuration is stored in an INI file for easy backup or transfer to another PC
  • Automatically connects to a previously opened serial port
  • Receive buffer cleared when a port is opened
  • In the service mode, both versions run as a client/server applicationallowing you to create, reconfigure and remove virtual ports remotely using a client-side part of VSP – useful for multi-port applications
  • Supports UAC (User Account Control)
  • VSP in TCP server mode uses 0.0.0.0 as a pre-entered IP address
  • Baudrate emulation - when no flow control is available
     

100% compatible devices

Applications

  • Using devices connected via RS-232 with legacy SW, no need to change existing utilities
  • Remote PBX management – PBX billing / accounting
  • Connecting payment terminals
  • Wireless remote serial port – through WiFi
  • UPS supervision over SNMP or with proprietary SW
  • Connecting a barcode reader to existing SW
  • Connecting serial printers and labelers
  • Remote control of industrial assembly lines, visualization

Description of HW VSP3

HW Virtual Serial Driver is intended primarily for devices produced by HW group, although it can be used for free as a universal driver that creates a virtual remote serial port, which redirects data to a predefined TCP/IP address and port.
In special applications (e.g. involving GPRS devices), the PC with the HW VSP driver can be set to operate in TCP Server mode, enabling the remote device to initialize the connection by sending any data to the remote port. Upon receiving RS-232 data, the converter establishes a connection with the PC and passes the data to the virtual COM port. Therefore, the scenario very closely resembles behavior of a real serial port.
When using HW VSP together with recommended devices produced by HW group, it is possible to change connection speed, parity, and other communication parameters (as well as to control any digital outputs and inputs) remotely on the fly via the RFC-2217 protocol, thus achieving a true remote serial port behavior.

Running as a NT service / in client-server mode

Ability to run as a service has been the main reason for developing the new version. Running HW VSP as a standalone application requires starting it under a logged-in user and therefore prevents autonomous operation on Windows servers. (At this time, HW VSP fully supports Windows 2000 Server and Windows 2003 Server. Support for Windows 2008 Server is being tested.) In this mode, HW VSP consists of a client-side part (setup GUI) and a server-side part (the service itself). Parameters of a VSP running on a remote server can be easily changed from a local PC. However, in order to improve stability, only one user may access the service and change virtual port parameters at a time. Furthermore, since service administration requires administrator privileges, securing a VSP against misuse is as simple as not installing the client-side part.
Note: From the user point of view, using HW VSP in service mode has many advantages. However, on Windows XP SP2/Vista/2003 Server, it is necessary to manually configure the firewall to enable the appropriate communication ports or the entire application (by default Program Files\HW group\HW VSP3s\HW_VSP3s_srv.exe for the single-port version and Program Files\HW group\HW VSP3\HW_VSP3_srv.exe for the multi-port one). Firewall dialog control is currently under development.

Baudrate emulation

In the previous version, HW VSP was fully transparent to the client software and did not restrict the communication flow in any way. Hence, the client SW had to send the data to the serial port using a defined communication speed, or use flow control (handshake). Otherwise, data were sent to the Ethernet / Internet with the maximum speed possible, often in the 10 Mbps range. When the buffers in VSP filled up, data started to be thrown away. Now, it is possible to enable the Strict Baudrate Emulation option in the Settings tab to ensure that VSP communicates with the client SW using the speed that is currently selected for the port.
Note: The Strict Baudrate Emulation option is only available when connected to HW group devices and with NVT support enabled.

Purging transmit and receive buffers

The option allows to clear Ethernet receive and transmit buffers when the port is opened. This ensures that the client application does not receive any previously received data (e.g. sent in a previous session) that could cause problems.

Automatic connection to previously opened port

This function allows connecting VSP to the port previously created and opened by the client application. This function is useful for servers, where it eliminates the need to close the corresponding virtual port before restarting server or the VSP service.

Configuration stored in an INI file

With the introduction of the multi-port version, VSP configuration is now stored in an INI file instead of the system registry. Therefore, configuration can be easily backed up or restored to another PC or server simply by copying the file and restarting the service. The INI file contains a complete VSP configuration, enabling the user to create a custom graphical interface to generate the INI file. Upon restarting the service, the INI file is loaded and the port parameters are changed - no need to study the complexities of controlling services. WC VSP for WirelesCOM is an example of such a customized application.

Works with Windows 8

HW VSP 3 now fully supports the Windows 8. UAC (user switching) support is also fully functional now, including functionality in a domain. When HW VSP is run as a service, all users can control it. 

Installing HW VSP3

HW VSP 3 is freeware; you can download it free of charge HERE. The software is available in a single-port and multi-port version (development is in the final stage now). Installation is straightforward, except for Windows Vista, where it is necessary to allow the installer to elevate its privileges.
Installation procedure:
  • Run the “HW VSP Setup 3.0.23 single.exe” installation program.
  • Step 1: The welcome screen is displayed. Click “Next” to proceed to the next step of the installation, or click “Back” to return to the previous step.
  • Step 2: The basic product information is displayed.
  • Step 3: Select the location where to install the driver.
  • Select installation type – Client-Server / Standalone or Custom.
  • Step 4: Choose a name for the folder to create in the Start menu.
  • Step 5: Select whether you want to create a shortcut on the Desktop.
  • Step 6: The entered data are displayed for verification.
  • Step 7: Confirm the installation.
  • Step 8: HW VSP will prompt you to agree with adding HW VSP to the list of exceptions for Windows Firewall. Permission is necessary for correct operation. If you deny the permission, you will have to add the application and the service to the list of exceptions manually.
If the installation is successful, the following window appears. If you check the “Launch HW_VSP” box, the program is started after completing the installation. It is not necessary to restart the computer after the installation. You can start HW VSP by clicking the “VSP” icon (icon with a red arrow).
Note: When installing HW VSP in Client/Server mode or using it in the Server mode on Windows XP SP2/Vista/2003 Server, it is necessary to manually configure the firewall to enable the appropriate communication ports or the entire service (by default Program Files\HW group\HW VSP3s\HW_VSP3s_srv.exe for the single-port version and Program Files\HW group\HW VSP3\HW_VSP3_srv.exe for the multi-port version). Firewall dialog control is currently under development.

Configuring the connected device

Before connecting to the VSP, it is necessary to configure the remote device according to its manual. If you use one of our devices, make sure to check the following parameters.
Most important parameters:
  • IP address of the remote device
  • IP port
  • Gateway
  • Mask
  • TCP/IP mode - TCP Server / Passive mode
  • Network Virtual Terminal (NVT) - On (only for recommended HWg devices)
  • Serial port parameters
Security
All configuration settings in HW VSP3 are password-protected. To enter the password, press the Login button. The default password is "admin". You can change your password with the HW_VSP3s_passwd.exe application that is available at Program Files\HW group\HW VSP3s\.

UDP Search

Run HW VSP and switch to “UDP Search” tab. After clicking Search modules, the Modules MAC Listdisplays a list of devices found in the local network segment.
Click Use this IP to set the IP address and the incoming port number of the selected device as the current device address for HW VSP to work with.


Virtual Serial Port

The main tab displays basic information about establishing the connection and its progress. Here you can create or delete a virtual serial port using the “Create COM” and “Delete COM” buttons respectively.
Click “Show Log” to display the program log that can simplify troubleshooting.
  • VSP pane
    List of serial port settings.
  • LAN pane
    Displays Ethernet connection status.
  • Counters pane
    Volume of the data transferred and requests queued.
  • IP Address
    IP address of the remote serial port. The value can be taken automatically from the UDP tab.
     
  • Port
    Incoming port of the remote serial port device. Your PC opens the TCP/IP connection and sends data to this port.
      
  • Port Name
    Number of the Virtual Serial Port being created – select a port number from COM2 to COM20.
     
  • External NVT Commands Port
    HW VSP opens the specified TCP port on your PC, where it receives NVT control commands for controlling I/O pins and passes them over the connection to the remote device.
    For example, a proprietary utility processes barcode data and your program (e.g. the HWg SDK example) controls I/O pins through VSP and the specified port – see the Block diagram.



    If you need to create more virtual serial ports on a single PC, you can use the multi-port version of HW VSP.
  

Settings

The “Settings” tab allows you to set up all functions supported by the virtual serial port.
Caution: These settings apply to the HW VSP utilityonly. They do NOT influence the remote device. Remote device properties are set according to its manual (e.g. via the Hercules utility in case of HW group products).
  • Log files enabled
    Logs all communication to a .log file.
  • Create VSP Port at HW VSP startup
    If this box is checked, all virtual ports are recreated when HW VSP is started.
  • TCP Server Mode
    Activates VSP as a TCP/IP server. The driver then behaves as a TCP Client/Server device - this means that the first party to receive any data switches over to Client mode and establishes the connection. In the TCP server mode, IP address is automatically preset to 0.0.0.0 and TCP port is set to current COM port number + 3000 (e.g. COM3 = TCP port 3003). The port can be changed. Pay attention to the firewall settings!
  • Purge Buffers when Port is Opened
    Clears transmit and receive buffers upon opening the port. This ensures that no leftover data from a previous session are sent or received. However, this also deletes any data received before the port is opened (e.g. during PC startup).
  • Connect to device even if VSP Port is closed If this box is checked, the connection is established immediately after the virtual port is created, even if no application is using the port. As a result, data sent when the port was open but unused will be lost. The device sends data even if you don’t “listen” for them.
  • Use NOP to Keep Connection
    + Renew automatically 
    Expects a testing NOP to check for module presence. If a module was unreachable and is rediscovered (starts to respond again), the connection is reestablished either immediately (“Renew automatically” checked), or as soon as VSP sends new data to the TCP socket (“Renew automatically” unchecked).
  • NVT
    Click “NVT Enable” to enable RFC2217 support and detection of our remote ports. Remember to activate NVT support on the corresponding device as well. After activating NVT commands, it is possible to activate the following parameters in the same way:
    • Remote port setup – sends control information to the remote port according to VSP settings on your PC. If your terminal software (e.g. Hyperterminal) changes the baudrate to 19200Bd and this feature is active, the VSP driver sends a NVT command (according to the RFC2217 standard) to the remote TCP/IP serial port and changes its baudrate, too.
    • Keep Connection – your TCP device closes an open TCP/IP connection after 50 seconds of inactivity. This function lets you keep the connection open (transfers 2 bytes every 5 seconds).
  • Strict Baudrate Emulation
    Limits the application-to-VSP and TCP-to-VSP transfer rate according to the baudrate of the open serial port.
  • Save Settings to INI file Saves current configuration in the INI file.

Advanced

  • Connection to Service
    Allows you to specify whether the GUI connects to the service running on the same PC, or change IP ports for the communication.
    • Local Machine – it is possible to change the port number for the GUI to service communication, e.g. in case of conflicts.
    • Remote Machine – Allows the client software to connect to a remote service, e.g. in situations where Remote Desktop is not available or suitable.
  • Reconnect
    Reestablishes the connection of the client interface to the running service, e.g. when the connection is lost, or establishes the connection of the local client portion to a remote service that runs for instance on a server.
  • Report VSP Setting
    Displays current configuration of the remote device (if TCP Setup is enabled on the device using the standard port 99).
  • Show Log
    Displays a logfile of VSP3 activity.

License – Distribution and Usage Conditions

Even though a license fee is not paid for the use of the Freeware Version software, it does not mean that there are no conditions for using such software:
  1. The Licensee will not have any proprietary rights to the Software. The Licensee acknowledges and agrees that the Licensor retains all copyrights and other proprietary rights in and to the Software.
  2. The Licensee must reproduce all copyright notices and any other proprietary legends on any copy of the Software.
  3. The Licensee may not disassemble, reverse-engineer, modify or alter in any way the installer program without the Licensor’s specific approval. The Licensee is not authorized to use any plug-in or enhancement that permits to save modifications to a file with the Software licensed and distributed by the Licensor.
  4. The Software under this License may contain the components developed by third-parties. The structure, organization and code of such components are the valuable trade secrets and confidential information of the third-party and are protected by copyright and third-party license agreement. The Licensee may not:
    • 4.1 incorporate such third-party components into software and hardware, developed by the Licensee, without the third-party’s special permission;
    • 4.2 provide such third-party components to accompany software and hardware, sold by the Licensee, without the third-party’s special permission.
  5. Private & Commercial license of HW VSP
    • 5.1 Private use license
      There are no restrictions to use and distribution of this software by private individuals; however, we kindly ask that you add a link to your website (or blog) that points to our website, www.HW-group.com, preferably in the form shown below.
    • 5.2 Commercial license
      Organizations and other legal entities may use and distribute this software only if they display a link to thehttp://www.HW-group.com  named as “Using HW VSP powered by HW group” on the website on the company or if they receive authorisation from HW group in written form.
If you distribute the software without publishing the link as described, you violate our copyright and we may take legal action against you.
Suggested link appearance
Source code for your WWW pages
HW VSP
Free Virtual Serial Port to connect any TCP/IP Terminal server to your Windows as a virtual serial port (e.g. COM 7). Produced by www.HW-group.com.
<b><a href="http://www.hw-group.com/products/hw_vsp/index_en.html">HW VSP</a></b><br>
Free Virtual Serial Port to connect any TCP/IP Terminal server to your Windows as a virtual serial port (e.g. COM 7). Produced by <a href="http://www.HW-group.com" target="_blank">www.HW-group.com</a>.
HW VSP
Free Virtual Serial Port to connect any TCP/IP Terminal server to your Windows as a virtual serial port (e.g. COM 7). Produced by www.HW-group.com.
<a href="http://www.HW-group.com"><img src="http://www.HW-group.com/download/hwg_ikona88x31.png" width="88" height="31" hspace="3" vspace="0" border="0" align="right"></a> <b><a href="http://www.hw-group.com/products/hw_vsp/index_en.html">HW VSP</a></b><br>
Free Virtual Serial Port to connect any TCP/IP Terminal server to your Windows as a virtual serial port (e.g. COM 7). Produced by <a href="http://www.HW-group.com" target="_blank">www.HW-group.com</a>.
<a href="http://www.HW-group.com"><img src="http://www.HW-group.com/download/hwg_ikona88x31.png" width="88" height="31" hspace="3" vspace="0" border="0"></a>
HW VSP - Produced by www.HW-group.com.<b><a href="http://www.hw-group.com/products/hw_vsp/index_en.html">HW VSP</a></b> - Produced by <a href="http://www.HW-group.com" target="_blank">www.HW-group.com</a>.
Note: You may save the icon image locally where your web is hosted; however, we prefer linking to the image at the HW group website, as the example code shows.

FAQ & Support

Q: Is it possible to use HW VSP to interconnect 2 serial ports on 2 different PCs over the Ethernet?
A: No. HW VSP only talks to a physical unit – PortBox2, IP Relay2, etc. Although it is possible to connect two HW VSPs (TCP Client and TCP Server), it is not possible to forward the data to a physical COM port of the PC.
Q: Can I use the Single port version with generic TCP/IP to serial port converter (Terminal server)? 
A: Yes. You just have to respect the licence coditions.
Q: Can I use the Multi port version with generic TCP/IP to serial port converter (Terminal server)? 
A: No. It's dedicated to HW group sevices only.

Ordering

HW VSP is available for download free of charge. However, you may order the source code in several variants detailed in table below. Please contact us for pricing and other info.
ProductDescription
freeHW VSP3 Single Port
Free version under the licence.
on requestHW VSP3 Source codes & other


DOWNLOAD & Links


沒有留言:

張貼留言

113 學年度第 1 學期 RFID應用課程 Arduino程式

113 學年度第 1 學期 RFID應用課程 Arduino程式 https://www.mediafire.com/file/zr0h0p3iosq12jw/MFRC522+(2).7z/file 內含修改過後的 MFRC522 程式庫 (原程式有錯誤) //定義MFRC522...